other prime movers should be anal ysed while driving the mixer unit under fully loaded conditions to determine that the

prim mover is not overloaded and thus putting out more than rated torque. If it is determi ned that overload

does exist, the unit should be stopped and steps taken to either remove the overload or contact Mixertech to determine

suitability of the gear driv under observed conditions. Once the mixer has been delivered to site and installed, check the following items:- This is known as ' RAMBO' 1. Rotation - Is the mixer going around in the correct direction. 2. Assembly - Is the mixer assembled correctly, especially the impeller - check the GA drawing 3. Mounting Arrangement - Check the gearbox is level and the shaft is vertical. 4. Bolting - Are all bolts torqued to the correct readings. 5. Oil - Check oil level and grade in gearbox. Once these simple five steps have been completed hot commissioning can commence.If during hot commissioning problems occur, heck the following trouble shooting charts for possible causes. Bredgar Road, Gillingham, Kent, ME8 6PN Tel: 0 3 .Price: sales Siemens Flender mixertech.co.ukFax: 0 3 Internet: Germany mixertech.co.uk _______________________________________________________________________________ Problem : The electrical motor constantly trip out or is running at high temperature. Note : Most motors are to Class , temperature will rise which gives an operating temperature to 1 degr ees . Direct sunlight an high ambient temperatures could cause this to rise by as much as 1 degrees. ------------------------------------------------------------------------------------------------------ Inspection Action -------------------------------------